¹¤Òµ¼¶84Mbps DDM 1x9 SM Transceiver Module

84Mbps DDM 1x9 SM Transceiver Module

5.0/5 rating 1 vote

Specifications

  • ²úÆ·ÐͺÅ: FTTR-1301-XDX(XXXX)
  • ¼æÈÝÆ·ÅÆ: ȫϵÁÐ
  • ·â×°ÀàÐÍ: 1x9
  • ´«ÊäËÙÂÊ: 84Mbps DDM 1x9 SM Transceiver Module
  • ´«Êä¾àÀë: 0~160km
  • ·¢É䲨³¤: 84Mbps DDM 1x9 SM Transceiver Module
  • ÎüÊÕ²¨³¤: 84Mbps DDM 1x9 SM Transceiver Module
  • ÊÂÇéζÈ: ÉÌÒµ¼¶0¡æ¡«+70¡æ/¹¤Òµ¼¶-40¡æ¡«+85¡æ ¿ÉÑ¡
  • Êý×ÖÕï¶Ï: ´øDDM
  • ÎüÊÕѸËÙ¶È: 84Mbps DDM 1x9 SM Transceiver Module
  • ÎüÊÕѸËÙ¶È: 84Mbps DDM 1x9 SM Transceiver Module

Description

84Mbps DDM 1x9 SM Transceiver Module

Product Features

  • Multi-sourced 1 ¡Á 9 pin packaged
  • 1310nm FP Laser Transmitter
  • FC double receptacle 
  • Up to 20Km with 9/125¦Ìm SMF
  • Single 3.3V or 5.0V power supply
  • Digital diagnostic monitoring
  • TTL signal input and output
  • TTL logic level signal detect output
  • Wave solderable and washable with process plug inserted
  • Temperature ranges:

     ¡ª -40¡ãC to +85¡ãC 

Product Description

F-tone¡¯sFTTR-1301-20DFI series of transceiver modules are the perfect solution for Low-speed communication networks.The transceiver modules support data rates up 2Mbps to 84 Mbps. These modules are fully compliant with the Multi-sourced 1¡Á9 protocol.The transceiver modules suppliesthe TTL interface of 3.3V/5.0 Voltage and provide the system designer with products to implement arange of low-speed data and digital video transmission designs at the 2Mbps to 84 Mbps rate for fiber communications.

Application

  • Digital Video
  • PDH,SDH equipments

Absolute Maximum Ratings

Operating of the transceiver beyond the Absolute Conditions Listed in Table 1 will degrade or damage the product. It¡¯s not implied that the product would function above the recommended operating environment, it¡¯s possible to reduce the reliability and lifetime of device if Recommended Operating Environment is exceeded (Refer to table 2)

Table 1-- Absolute Maximum Conditions

Parameter

Symbol

Min

Max

Units

Storage Temperature

TST

-40

+85

¡æ

Operating Temperature

(CASE)

TOP

-40

+85

¡æ

Supply Voltage(3.3V)

VCC3

0

+3.8

V

Supply Voltage(5.0V)

VCC5

0

+6.0

V

Relative Humidity

RH

5

95

%

Input voltage

VIN

0

VCC

V

Lead Soldering Temperature & Time

-

-

260/10

¡æ/S

Table 2-- Recommended Operating Environment

Parameter

Symbol

Min

Typ

Max

Units

Supply Voltage

3.3V power

VCC3

3.1

3.3

3.5

V

Supply Voltage

5.0V power

VCC5

4.75

5.0

5.25

V

Ambient operating Temperature

(CASE)

TOP

-40

-

+85

¡æ

Supply Current

ITX+IRX

-

150

200

mA

Optical Parameters

Table 3 FTTR-1301-20DFI Transceiver Optical and Electrical Characteristics

(Ambient Operating Temperature Ta=-25¡ãC, VCC =5.0V)

Parameter

Symbol

Min

Typ

Max

Units

Transmitter

Data rate

B

2

-

 84

-Mb/s

Output Center Wavelength

¦ËC

1260

1310

1360

nm

Output Spectral width (RMS)

¦Ë

-

-

4.0

nm

Average Optical Output Power

Po

-12

-

-1

dBm

Extinction Ratio

EXT

10

-

-

dB

Optic Output Eye: Compliant with Bellcore TR-NWT-000253 and ITU recommendation G.957

Receiver

Receiver Sensitivity

PMIN

-

-

-35

dBm

Maximum Input Power

PMAX

-3

-

-

dBm

Signal Detect -- Asserted

PA

-

-

-35

dBm

Signal Detect -- Deasserted

PD

-46

-

-

dBm

Signal Detect - Hysteresis

PHYS

0.5

-

-

dB

Electrical Parameters

Table 4 (Ambient Operating Temperature Ta=25¡ãC, VCC = 5.0V)

Parameter

Symbol

Min

Typ

Max

Units

Transmitter

Power Supply Current

ICC

-

-

100

mA

Data Input Current - Low

IIL

-350

-

-

¦ÌA

Data Input Current - High

IIL

-

-

350

¦ÌA

Data Input Voltage - Low

VIL

 

-

0.7

V

Data Input Voltage - High

VIH

2.0

-

 

V

Receiver

Power Supply Current

ICC

-

-

100

mA

Data Output Voltage ¨C Low

VOL

 

-

0.7

V

Data Output Voltage ¨C High

VOH

2.0

-

 

V

Signal Detect Output Voltage-Low

VOL

 

-

0.7

V

Signal Detect Output Voltage-High

VOH

2.0

-

 

V

Digital diagnostic monitoring Characteristics

Table 5 Digital diagnostic monitoring Characteristics

Parameter

Symbol

Range

Accuracy

Transceiver Internal Temperature Accuracy

T

Recommended Operation Condition

¡À3¡æ

Transceiver Internal Supply Voltage Accuracy

VCC

Recommended Operation Condition

¡À3%

Laser Bias Current Accuracy

ID

ID:1-100mA, Recommended Operation Condition

¡À10%

Tx Output Power Accuracy

PO

PO:-12~-1dBm, Recommended Operation Condition

¡À3dBm

Rx Input Power Accuracy

PI

PI:-35~-3dBm, Recommended Operation Condition

¡À3dBm

EPROM Serial ID Memory Contents:

Table 6Serial ID Memory Contents

Data Address

Size (Byte)

Name of Field

Description

Base ID Fields

0

1

Identifier

XXX

1

1

Ext. Identifier

function is defined by serial ID only

2

1

Connector

FC Connector

3-10

8

Transceiver

Transceiver Codes

11

1

Encoding

NRZ

12

1

BR, Nominal

100Mbps

13

1

Reserved

 

14

1

Length(9¦Ìm)km

Transceiver transmit distance

15

1

Length(9¦Ìm)100m

16

1

Length(50¦Ìm)10m

17

1

Length(62.5¦Ìm)10m

18

1

Length(Copper)

Not compliant

19

1

Reserved

 

20-35

16

Vendor Name

vendor name: F-tone

36

1

Reserved

 

37-39

3

Vendor OUI

 

40-55

16

Vendor PN

Part Number: ¡°NTR-xxxxx¡±

56-59

4

Vendor rev

4.0

60-61

2

Wavelength

Transceiver wavelength

62

1

Reserved

 

63

1

CC_BASE

Check code for Base ID Fields

Extended ID Fields

64-65

2

Options

TX_FAULT, TX_DISABLE and Loss of Signal implemented.

66

1

BR, max

 

67

1

BR, min

 

68-83

16

Vendor SN

Serial number

84-91

8

Date code

Manufactory date code

92

1

Diagnostic Monitoring Type

Digital diagnostic monitoring implemented, ¡°externally calibrated¡± is implemented, RX measurement type is ¡°Average Power¡±.

93

1

Enhanced Options

Optional Alarm/Warning flags implemented for all monitored quantities, Optional Soft RX_LOS monitoring implemented.

94

1

SFF-8472 Compliance

Includes functionality described in Rev 9.3 SFF-8472.

95

1

CC_EXT

Check sum for the extended ID Fields

Vendor Specific ID Fields

96-127

32

Vendor Specific

Depends on customer information

Table 7  Serial ID Memory Map: A2

Address

Name of Fields

Description

0~1

Temperature High Alarm

110¡ãC

2~3

Temperature Low Alarm

-45¡ãC

4~5

Temperature High Warning

100¡ãC

6~7

Temperature Low Warning

-40¡ãC

8~9

VCC High Alarm

5.5V

10~11

VCC Low Alarm

3.0V

12~13

VCC High Warning

5.4V

14~15

VCC Low Warning

3.1V

16~17

Bias High Alarm

80mA

18~19

Bias Low Alarm

0mA

20~21

Bias High Warning

70mA

22~23

Bias Low Warning

0mA

24~25

TX Power High Alarm

-3dBm

26~27

TX Power Low Alarm

-13dBm

28~29

TX Power High Warning

0dBm

30~31

TX Power Low Warning

-12dBm

32~33

RX Power High Alarm

-1dBm

34~35

RX Power Low Alarm

-36dBm

36~37

RX Power High Warning

-4dBm

38~39

RX Power Low Warning

-35dBm

40~55

Reserved

 

56~94

Calibration Coefficients

 

95

Check Sum

Check Sum byte for 0 to 94

96~97

Measured Temperature

Scale: 1/256¡ãC

98~99

Measured VCC

Scale: 100uV

100~101

Measured Bias Current

Scale: 2uA

102~103

Measured TX Power

Scale: 0.1uW

104~105

Measured RX Power

 

106~109

Reserved

 

110

Optional Status/ Control Bits

 

111

Reserved

 

112~119

Alarm and Warning Flags

Corresponding flags are set when internal  monitoring values exceed the setting levels.

Pin Assignment & Signal Definition

Table 8¡ªConnector pin assignment

Pin #

Pin Name

Description

1

Rx VEE

Receiver Signal Ground

2

RD+

Receiver Data Out

3

SCL

Serial Clock Line

4

SD

Signal Detect

5

Rx VCC

Receiver Power Supply

6

Tx VCC

Transmitter Power Supply

7

SDA

Serual Data Line

8

TD+

Transmitter Data In

9

Tx VEE

Transmitter Ground

Ordering information

Part Number

Product Description

FTTR-1301-20DI

2~484Mbps DDM 1X9 SM Transceiver Module ,SC , -40?C ~ +85?C

FTTR-1301-20DTI

2~484Mbps DDM 1X9 SM Transceiver Module ,ST , -40?C ~ +85?C

FTTR-1301-20DFI

2~484Mbps DDM 1X9 SM Transceiver Module ,FC , -40?C ~ +85?C

 

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must bespecifically confirmed in writing by F-tone Networks before they become applicable to any particular order orcontract. In accordance with the F-tone Networks policy of continuous improvement specifications may changewithout notice.

The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

 

Search

sitemap¡¢ÍøÕ¾µØͼ