+86-028-85255257
ÌØÕ÷£º
¡ñ Epoxy free in optical path
¡ñ Stable and reliable
¡ñ Compact size
Ó¦Óãº
¡ñ Both Add/Drop
¡ñ Telecom networks
¡ñ Metro networks
Parameters£º
Description |
Unit |
Min |
Typical |
Max. |
||
Optional channel loss |
dB |
2.5 |
3.5 |
|||
Pass band width |
nm |
13 |
15 |
|||
Flatness |
dB |
0.3 |
0.5 |
|||
Adjacent channel isolation |
dB |
30 |
35 |
|||
Non adjacent channel isolation |
dB |
40 |
45 |
|||
Directivity |
dB |
55 |
||||
PDL |
dB |
0.2 |
||||
PMD |
ps |
0.2 |
||||
Max. power |
mw |
300 |
||||
Pass channel insertion loss |
P |
dB |
2.5 |
3.0 |
||
A |
3.0 |
3.5 |
||||
Channel wavelength |
nm |
1471 1491 1511 1531 1551 1571 1591 1611 Can be selected on request or any 4channel between 1260-1625 |
||||
Operating temperature |
°C |
0 ~+70 |
||||
Storage temperature |
°C |
-40 ~+85 |
||||
Package |
mm |
50(L)X50(W)X6(H) |
Paging Dimensions :
Order Information:
FT-AJ-CCWDM18- |
XXXX- |
X- |
X- |
XX- |
X- |
X |
Wavelength |
Grade |
Pigtail Type |
Length |
connector |
package |
|
1471 1491 1611 |
P A |
0=bare fiber 1=900um loose tube 2=2mm cable 3=3mm cable |
05=0.5m 10=1.0m 15=1.5m |
0=none 1=FC/PC 2=FC/APC 3=SC/PC 4=SC/APC 5=LC 6=Others |
0=Standard 1=Special
|
Important Notice
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.